FFT Y-Output Values don´t correspond expactions regarding Input

$
0
0

Hi

i am quite stuck with this problem and could really need help:

 

my Situation right now:

- concatenated 121 files with each 21000 measurments each, to a torque channel ( MyR ) and a rpm channel( Rotspd ) via skript

- created a numerik time channel ( time ) starting a 0-72600s, with 2541000 number values based on the number of files and measurements.

- choose FFT (One Time Signal), Time channel: time, Signal channel: MyR, Window type: Retancle, FFT: Amplitudepeak, Average Amplitude:    None, Third/Oktave: No

( PIC: 1-3 )

 

my Problem:

after applying the FFT, i displayed the results and :

-the original measurment values&peaks do not correspond to the resulting amplitude peaks

 

i am using:

DIAdem 2015

15.0. (64 Bit)

 

How do i achieve the output values regarding peaks in my FFT output ?

Is there a better signal analyse funktion in Diadem besides FFT which results in Frequency(X) and Amplitude(Y) ?

 

Kind regards and big thanks in advance

Knicks